Prins lpg switch. We also offer CNG and LNG .

Prins lpg switch - The orange LED on the switch flashes . 0 , and VSI DI 3. By means of the tank indication LED’s, the fuel level can be read out. LPG switch ac stag led 600 petrol/gas suitable for Qbox, Qnext, Qmax dpi 400 S TA G GOFAST systems (ex. Page 7 Prins VSI LPG reducer • Mount the reducer to the body of the vehicle in the engine compartment, never on the engine! • Mount the reducer so that it is easy to adjust the pressure. Системите Prins VSI-3 DI и Prins VSI-2 DI 8 цилиндъра за директно впръскване покриват широка гама от най-новите автомобили. ValveCare additive: Injector rail Prins : LPG E4-67R-010093 Lock-off valve OMB : E8-67R-014327 CNG E4-110R-000021 Lock-off valve Valtek : E4-67R-010041 Filter unit T1 / T2 Prins : LPG E4-67R-010096 Injector Keihin :LPG E4-67R-010092 CNG E4-110R-000028 CNG E4-110R-000020 Filter unit Keihin : LPG E4-67R-010177 Page 7: Mounting And Connection Points Prins VSI 2. IIRC that’s how the PRINS LPG sequential injection system Prins VSI LPG Reducer with MAP connection. This LPG switch is compatible with the Prins VSI-2. Engine control relay B7 C7 B6 C6 B5 t° t° Oxygen sensor 1 Bank 1 Oxygen sensor 1 Bank 2 injection module 1-2-3-4-5-6 Injection module Switch -Prins LPG switch vsi 2. Reference OE/OEM Number n buzzer, LPG 080/70062 IC LPG 180/700004/A IC, PRINS VSI switch with full indication of gas level with built-i. The CNG switch is not exchangeable with a LPG switch! 21 The VSI-2. LPG switch for installations: OPTIMA nano / OPTIMA EXPERT / OPTIMA PICO. Out of stock Compare LPG & NH3 Supply is an authorized distributor and installer of PRINS, propane AUTOGAS vehicle conversion systems. The switch is controlled by the VSI-2. version : n. 9/A0 and ex. For Prins VSI Reducer Gas injection systems and engines up to 250 kW (340 HP) with or without Turbo. Система за многоточково впръскване (MPI). 1 , VSI-2. 1. Injector rail Prins : LPG E4-67R-010093 Lock-off valve OMB : E8-67R-014327 CNG E4-110R-000021 Lock-off valve Valtek : E4-67R-010041 Filter unit T1 / T2 Prins : LPG E4-67R-010096 Injector Keihin : LPG E4-67R-010310 CNG E4-110R-000028 CNG E4-110R-000295 Filter unit Keihin : LPG E4-67R-010177 Page 7: Mounting And Connection Points The components that make up our VSI LPG-system are shown below. The fuel selector switch The fuel selector switch has two selection modes: 1. The listing is for software only, no cables included. 0 platform. - Temperature sensor integrated - External gas valve optional. LPG systems for cars are great at sw Mar 21, 2017 · Hey Guys<br><br>Hope anyone in the forum can shine a bit of light on my problem. 20. If the Prins logo illuminates then LPG is selected, if the status LED does not illuminate petrol is selected. Jan 6, 2018 · Hello everyone, I recently installed an old prins VSI LPG installation in my p38. txt) or read online for free. 0 fuel switch. Competitive price of autogas components. Returns or exchanges are NOT possible. Is there a way to adjust the temperature settings on the prins computer? And if yes, what would be the absolute minimum temperature Apr 6, 2025 · i have a problem with the logging of the LPG status. software : n. Engines running on LPG also produce much lower NOx emissions compared to engines running on diesel. Is there a way to change the switch voltage ? In the manual "(low state 0V - petrol, high state 3V and more - lpg)" But in thesoftware it is 5 Volts ? Thank you Prins VSI 2. This type of switch is suitable for the following LPG systems: - Vogels VGI - OMVL Dream XXI - Bigas SGISN - Tartarini - Elpigaz Stella - King - Zavoli - Emmegas. Prins VSI Switch LPG Type 1 - 7 wires Genuine Prins switch for Prins VSI 1 ECUs, part number is 080/70058 166023 £46. By using the selector switch it is possible to switch between LPG and petrol mode. This digital manual gives you general information about Autogas (LPG), and explains the Prins VSI system. Oct 21, 2020 · Prins Alternative Fuel Systems’ VSI-3 DI LPG system is suitable for vehicles equipped with direct injection (DI) engines. The VSI-2. The petrol/gas switch indicates the car's current mode (current fuel supply type: petrol/gas) and the gas level in the tank. CNG E4-110R-000083 . We offer our customers high quality, cost-effective and innovative solutions for a wide variety of engine types. Prins VSI Switch LPG Type 1 - 7 wires Genuine Prins switch for Prins VSI 1 ECUs, part number is 080/70058 166023 Add to Cart. Express service You will find us also on ebay Read reviews, place your order online! This training manual provides information about the Prins VSI-LPG system for converting vehicles to run on liquid petroleum gas (LPG). 99. Changeover Switch; Control Valves; ECU & Processors; Electrical Plugs & Terminals Pro Gas has been supplying and developing LPG conversion systems for over 20 Feb 7, 2020 · If the ECU doesn't see an RPM signal it will never change-over to LPG, and if it loses the RPM signal while running on LPG it may switch back to petrol without the driver knowing (no beeps from the switch etc). LPG Hoses. VSI LPG automobile accessories pdf manual download. Cup for France, Italy, Portugal. EPA-certified; Bi-fuel System (vehicle starts on gasoline; after the engine reaches a temperature of 43°C, it can operate using AUTOGAS or gasoline) Vehicle Specific Kits & Software Calibrations Автомобили 2024. As the vehicle has an Autogas tank and a petrol tank the total range can be extended to more than 1,000 km without refuelling. Also for: Vsi cng. Mounting the Fuel Selection Switch. Out of stock Compare Reducer SilverLine LPG Prins : E4-67R-010054 Lock-off valve OMB : E8-67R-014327 Lock-off valve Valtek : E4-67R-010041 Injector rail : LPG E4-67R-010093 CNG E4-110R-000021 Filter unit Prins : LPG E4-67R-010096 CNG E4-110R-000028 Computer SilverLine Prins: LPG E4-67R-010098 Sep 29, 2020 · The VSI-3 DI LPG-system is also equipped with a Prins multi-color switch, a Prins filter, an LPG tank in the spare wheel compartment and the filling point near the petrol filling point. NOT SUITABLE FOR traditional mixing piece (venturi ♦ LPG mode: status LED on-Switch over indication: ♦ LPG <> Petrol : status LED off/beeper beeps 1x ♦ Petrol <> LPG : status LED on/ beeper beeps 2x-Tank level indication (always on) ♦ 5 indication LED’s (colour application depending)-Diagnostic warning ♦ Switch back to petrol mode ♦ Diagnosis/system check LED illuminates ♦ The LPG tank is (usually) installed at the location of the spare wheel, so no loss of luggage space; The LPG filling point is usually placed behind the flap next to the gasoline connection; A Prins switch shows you how full your LPG tank is and with which you can switch manually between driving on LPG or gasoline, if desired. Possibility of adding another adapter for other countries Filling of gas cylinders prohibited in France and ItalyAdapter sold without seal! Reducer VSI LPG Prins : E4-67R-010054 Lock-off valve OMB : E8-67R-014327 3-pole micro connector Connect the 3-pole connector to the Prins fuel selection switch. The LPG control unit has a built-in buzzer, it is easy to assemble and easy to use. 0 LPG Prins VSI Reducer VSI-2. LPG mode: System LED illuminated (Prins logo) Basics of Conversion Get a Quote Get a quote to convert your car to LPG using quality Prins products Why should I convert Some good reasons to run your vehicle on LPG. Системите Prins VSI-3 DI и Prins VSI-2 DI за директно впръскване покриват широка гама от най-новите автомобили. The LPG system switches to LPG LPG tank empty? but engine stalls immediately Not running on all cylinders on lpg Check parameter 10, number of cylinders. Prins LPG & Automotive Accessories Warranty What you’re covered for. The VSI-I fuel switch _____ 21 The VSI-2. With the VSI system, Prins strives for optimal emissions and … Continue reading "Vapour Injection- VS2" Автомобили 2024. With engine on but not started, switch to petrol then immediately switch back to LPG and hold the LPG button down until the lead goes yellow, then the car should start on LPG until next start cycle. During low level (LPG tank Prins VSI Switch LPG Type 1 - 7 wires . ECU (Electronic Control Unit) 3. 0 systems. Prins VSI LPG-Filter Set 180/80044/D plastic 2 outlets 16x11x11mm. Apr 2, 2025 · Autogas GPL Code 080/000100/A. Show more. VSI-2-0 CNG Keihin VSI-2-0 CNG Ventrex. There are various types of Prins RPM module, something around matchbox size with a few wires coming out of it or something that looks LPG Switch with touch button and tank content indication. It describes the components and operation of the VSI-LPG system in detail. Prins wishes you a lot of driving pleasure. 6 V8 HSE on a 80Ltr Prins LPG System, which i adore and love and has now started to show problems, I bought her 2 years ago and she ran without any problems, this winter just gone her LPG systems wouldn't kick over to LPG, after a couple of minutes on petrol, so i checked online and read . WARNING! The right of withdrawal does not apply to electronic components. 10/A0 and newer) The VSI-I fuel switch _____ 21 The VSI-2. Welcome to Prins LPG & Automotive Accessories supplying Australia and New Zealand with quality Prins LPG conversion kits and components. Filter The VSI-I fuel switch _____ 21 The VSI-2. 0 , VSI-2. It is also a greener fuel; when running on LPG, your car emits up to 21% less CO2 and up to 95% less fine particulate matter compared to petrol. Petrol mode: System LED extinguished (Prins logo) 2. Bio-LPG, which is an even cleaner variant, will also be available soon. The ut comp switches back to gasoline. I have a 96 MKII P38 4. 0 DI computer ensures overall system control, safety and efficiency. The VSI system is the most advanced vapour injection system available on the market. Filling up the additive-reservoir will make driving on LPG possible again. The manual explains the LPG tank, reducer, injectors, computer and other 51 power feed switch 53 + LPG VLV 54 INJ simulator to LPG tank LPG Tank Circuit diagram 4 cylinder VSI red red - black twisted red - black twisted red - black twisted red - black twisted Engine control relay PRINS AUTOGASSYSTEMEN B Y GR B GR G R GR GR R R R-W G-W R B P-W G-W G-W G-W Y-W Y-W Y-W Y-W BR GR B O O G-Y R-B R R-B R-W B BR G G-W GR In this video I show fixing an LPG vaporiser and talk about other common faults and fixes for car LPG injection systems. CCY USB LPG Interface No. 0 fuel switch _____ 22 The Prins LPG reducer Sep 4, 2013 · The CNG switch is not programmable. The system uses a master/slave configuration where the engine management system's injection strategy is followed. When the fuel status LED (Prins logo) is illuminated the LPG mode is selected and when the fuel status LED (Prins logo) is off the petrol mode is selected. The orange LED on the switch Activate the LPG computer with the diagnostic program, using the F11 flashes function key. 15 The VSI-I fuel switch _____ 21 The VSI-2. Prins, part of Westport Fuel Systems, has been a pioneer in fuel system development of LPG, CNG, LNG and H2 (hydrogen) fuel systems, for more than 35 years. PRINS VSI LPG diagnostic software compatible with all PRINS VSI 1 models only. LPG fuel level indication The engine always starts on petrol. Adapter for filling 13Kg gas bottles. NOZZLES VOOR LPG-INJECTOREN; PRINS (VSI 2) ronde led LPG schakelaar 0,95 ohm In case the additive reservoir is empty, the Prins switch will indicate a blue exclamation mark (blinking), and the engine can run another 4 hours on LPG. The company was formed by Vernon who started working in the LPG conversion industry in 1983 and is a qualified motor mechanic, licensed LP Gas Fitter and has worked with both Prins and Poliauto systems. What happens to your car when it gets converted Basics of an LPG … Continue reading "Basics of Conversion" TS / 23-04-07 RK / 26-10-07 -1 JT / 26-10-07 1/1 080/72050 VSI wiring diagram 6 cylinder LPG (without connectors) 30 battery +12V 15 ignition switch Petrol ECU manufacturer : n. 2 , VSI DI 2. a. Gas Phase Filters. 0 switch is designed for the new VSI-2. 0 fuel switch _____ 22 The Prins LPG reducer PRINS (VSI 2) ronde led LPG schakelaar 0,95 ohm SCHAKELAAR FIAT TARTARINI • AIRGPL Tweedehands Tartarini / Fiat LPG schakelaar-Switch Geïntegreerde intermeter Vapour Injection- VS2 Vapour Sequential Injection VSI System VSI is an abbreviation for “Vapour Sequential Injection”. This switch is used in the OEM LPG installations of Dodge RAM (it is included in the current installations). pdf), Text File (. LPG-tank 2. 0 computer through LIN communication. Scroll down further for information about the fuel selector switch, refuelling LPG, fuel consumption, safety aspects, maintenance, troubleshooting, general directives and the warranty terms. Sep 4, 2013 · vsi_lpg - Free download as PDF File (. Conversion System Highlights & Overview. While driving it is possible to switch between both fuels by pressing the fuel selector switch. Prins VSI -3 “eVP Type 2” Gas Filters Set (16/12 This video help you to solve most common problem resulting to LPG switch blinking with service signal Connect SilverLine wire 13 to the petrol injector feed instead of ignition+. 0 fuel switch _____ 22 The Prins LPG reducer The new, cheap and reliable gasoline PRINS VSI gas switch, sequence. 0 PRINCE Diesel Blend. Out of stock Compare Oct 28, 2022 · As already mentioned, many sequential LPG injection systems allow you to start on LPG. The tank valve gets activated with +12 volts, after a few seconds it gets reduced to 4,4 Volts. ACCESSOIRES. Electrical Connections. Prins VSI 2. Switch 4. 0 Prins eVP-500 Reducer. After this period the engine does only run on petrol and the exclamation mark will stay visible. We would like to show you a description here but the site won’t allow us. Possibility of adding another adapter for other countries Filling of gas cylinders prohibited in France and ItalyAdapter sold without seal! From now on, a digital version of Prins’ driver’s guide is available online at our website. Suitable for the following Gas Systems: PRINCE VSI PRINCE VSI 2. Quick view. We also offer CNG and LNG VSI-2. Evaporator (eVP-500) 5. With the VSI system there is no difference between driving on LPG or with petrol. The main components meet the same standards as OEM-parts, and have been specifically developed for LPG and CNG systems. 0 Switch Hall 0-95 Ohm. Genuine Prins switch for Prins VSI 1 ECUs, part number is 080/70058 View and Download Prins VSI LPG installation manual online. They satisfy the most demanding regulations and certification standards. 0- газова инжекционна система, отговаряща на най-високите изисквания- R115. According to the company, the Prins AFC-3. Prins Lpg; Pvl Ignition; PROTON Gti; Pvris White Noise; Lpg Central Heating; Boss LS2; Boss GP-10; Computer VSI- 4 / 6 Prins: LPG E4-67R-010098 . Fuel status LED (Prins logo) does not illuminate: Petrol mode (driving on petrol). Switching from petrol to LPG and reverse While driving it is possible to switch between both fuels by pressing the fuel selector switch. Prince VSI LPG-Filter Set eVP type 2-180/800506 - 2 outlet Switch -Prins LPG switch vsi 2. The LPG system switches to LPG but engine stalls View online or download Prins VSI Installation Manual. Wishlist. 0 fuel switch _____ 22 The Prins LPG reducer SWITCH / INTER LPG; SCHAKELAAR AEB 722A / CARBURATEUR AE2885-M47; Home. Depending on the engine temperature and after the system check, the VSI system will automatically switch over to LPG. In this driver’s guide you can find all necessary information such as: important information about driving on Autogas (LPG), system instructions and maintenance. With this digital guide you have access to this manual at any place and time. Now it takes quite a lot of time to heat up and switch over from petrol to LPG. Автомобили 2024. Sign In Upload. 19. For the cable, check out Autogas conversions parts. The fuel status LED indicates the selected fuel. Control units, LPG reducers, gas injectors, sensors, harnesses and accessories. 17. uayerbe jrr jinq vnzvv qyylnc oabw jmro colq cdfdfow tzai